EDAN SE-1 ECG – 1 channel with monitor

EDAN SE-1 ECG – 1 channel with monitor

Description

The new standard in single-channel Electrocardiography. SE ECG units represent the best in quality, performance and price. They have advanced features, an ergonomic design and sturdy construction.
Single-channel ECG with adjustable graphic display parameters can be set according to the user’s needs.
• High resolution thermic printer
• Power through power grid or lithium rechargeable battery
• Digital filters, anti slip, AC, muscular EMG with automatic base line for print lines optimization
• RS232 serial port
• Manual/automating operating modes
• Electrodes positioning lead
• Lead: Standard 12 leads
• Acquisition mode: Single
• Sensitivity: 2.5, 5, 10, 20, mm/mV
• Input impedance: > 50 MO
• Filter:
– EMG Filter 35 Hz (-3 dB)
– AC/DFT Filter 50 Hz/60Hz DFT Fliter 0.05/0.15/0.25/0.35/0.5/0.67 Hz
– (-20 dB)

• Recording mode: Auto/Manual
• Rhythm lead: Any lead selectable
• Safety standard: I EC I/CF
• Power supply:
– AC: 100 V-115 V/220 V-240 V, 50/60 Hz
– Rechargeable Li-ion battery: voltage 14.8 V
– More than 3 hours continuous operation with battery supply

• Data storage: –
• Thermal paper: 50 mm x 30 m
• Paper speed: 25mm/s, 50 mm/s (± 3%)
• 12.5mm/s, 25mm/s, 50 mm/s•Dimension: 288 x 210 x 70 mm
• Weight: 2.3 kg (with battery)

Category:

Description

The new standard in single-channel Electrocardiography. SE ECG units represent the best in quality, performance and price. They have advanced features, an ergonomic design and sturdy construction.
Single-channel ECG with adjustable graphic display parameters can be set according to the user’s needs.
• High resolution thermic printer
• Power through power grid or lithium rechargeable battery
• Digital filters, anti slip, AC, muscular EMG with automatic base line for print lines optimization
• RS232 serial port
• Manual/automating operating modes
• Electrodes positioning lead
• Lead: Standard 12 leads
• Acquisition mode: Single
• Sensitivity: 2.5, 5, 10, 20, mm/mV
• Input impedance: > 50 MO
• Filter:
– EMG Filter 35 Hz (-3 dB)
– AC/DFT Filter 50 Hz/60Hz DFT Fliter 0.05/0.15/0.25/0.35/0.5/0.67 Hz
– (-20 dB)

• Recording mode: Auto/Manual
• Rhythm lead: Any lead selectable
• Safety standard: I EC I/CF
• Power supply:
– AC: 100 V-115 V/220 V-240 V, 50/60 Hz
– Rechargeable Li-ion battery: voltage 14.8 V
– More than 3 hours continuous operation with battery supply

• Data storage: –
• Thermal paper: 50 mm x 30 m
• Paper speed: 25mm/s, 50 mm/s (± 3%)
• 12.5mm/s, 25mm/s, 50 mm/s•Dimension: 288 x 210 x 70 mm
• Weight: 2.3 kg (with battery)